Flow Measurement

Multiple flow measurement technologies to measure liquids, gases, steam and corrosive fluids.

FlowmeterServiceWetted
Material
AccuracyRangesTemperature
Limit
Power
Requirement
Coriolis Mass
Flowmeter
Liquids and Gas304 SS, 316 SS
or Hastealloy C
0.1% or 0.2% or 0.5%For mass flow rates
please refer the catalog
Direct Mount: -58°F to 257°F (-50°C to 125°C)
Remote Mount: -58°F to 392°F (-50°C to 200°C)
18 to 28 VDC
or 85 to 220 VAC
Ultrasonic Clamp-On
Flowmeter
Compatible LiquidsSensor: Aluminum alloy
or Plastic alloy
1%1200A-S2: ½" to 4", 1200A-M2: 2" to 28",
1200A-HS: ½" to 4", 1200A-HM: 2" to 28"
32°F to 320°F (0°C to 160°C)1200A-100F1: 85 to 264 VAC or 24 VDC,
1200A-100M: 8 to 36 VDC
1200A-100H: 90 to 230 VAC or Ni-MH battery
Vortex
Flowmeter
Liquids, Gas, and Steam304 SS and 316 SS±1% of readingGas: 197 ft/s (60 m/s)
Liquid: 23 ft/s (7 m/s)
Steam: 230 ft/s (70 m/s)
Standard: 302°F (150°C)
Medium: 482°F (250°C)
High: 662°F (350°C)
13.5 to 42 VDC
Electromagnetic
Flowmeter
Compatible conductive liquidsElectrode Material: 316 SS or Hastealloy C
Liner Materials: PTFE or Hard Rubber
±0.5% of F. S.For flow range please refer the catalogSensor (Remote Mount): -50°F to 158°F (-45°C to 70°C)
Converter: -40°F to 122°F (-40°C to 50°C)
Direct Mount: 40°F to 122°F (-40°C to 50°C)
18 to 28 VDC or 85 to 220 VAC
Thermal Mass
Flowmeter
Air and Nitrogen316 SS±0.5% of FSSee Velocity ranges in Catalog-40°F to 302°F
(-40°C to 150°C)
13.5 VDC to 42 VDC
Orifice Meters
Tek-DP 1610A
Tek-DP 1610B
Tek-DP 1610C
Liquids and Gas304 SS, 316 SS, 316 SS as standard.
Monel, PP, PVC, PTFE coated
Standard -20 °F to 100 °F (-28 °C to 37 °C), optional
-40 °F to 1200 °F (-40 °C to 648 °C)
Cone
Flowmeter
Liquids and Gas304 SS, 316 SS,
316 SS as standard. Hastelloy-C,
Flow
Nozzle
Liquids and GasCarbon steel for weld in type, 304 SS, 304 SS, 316 SS,
316 SS for holding ring type and
Ni, Cr, Mo Alloy Steel for flanged type
Venturi
Meter
Liquids and GasAll standard materials available
Inline Ultrasonic
Flowmeter
Crude oils and other liquid hydrocarbons
including (potable /cooling) water tariff metering
+/- 0.10% accuracy
with a constant K-factor
Process: -20°C to +120°C
Ambient: -20°C to +55°C
110/220 VAC 50/60 Hz
or 18/32 VDC, 10W, isolation 1500V
WedgesFluids and Gases≤ ± 0.5 % of the actual flow rate
(Calibrated)
Standard at -20°F to 100 °F,
optional -40 °F to 1200 °F

ETA Process Instrumentation

19 Foster Street, Bldg. #6,
Peabody, MA 01960

Tel: (978) 532-1330
Fax: (978) 532-7325

Visit Our Sister Companies