Gas Sample Conditioning Systems for Emissions and Process Monitoring

  • Guide For CEMS and Process Analysis
  • Applications include Power Generation, Refineries, Petrochemical, Incineration and Water Treatment
  • Coolers/Probes, Sample Conditioning Systems, Ammonia & Acid Scrubbers, Portable Equipment
  • Notes on Baldwin’s Classic Cooler Line
    Baldwin’s Classic Cooler line has been replaced by the new Digital Cooler Line. This information is here for reference.

Perma Pure AS-Series Ammonia Scrubbers Specifications

Perma Pure AS-Series Ammonia Scrubbers Specifications
Model NumberAS-200-08-PSAS-200-08-PSHAS-200-08-SSAS-200-08-SSH
DescriptionPolysulfone shell with stainless steelPolysulfone shell with heater blanketAll 316 stainless steel constructionStainless steel shell with heater blanket
Maximum Pressure30 psig30 psig100 psig100 psig
Maximum Temperature125°C* See Note130°C (200°C with hex bolt replacing thumbscrew)* See Note
Ports1/4″ FNPT1/4″ FNPT1/4″ FNPT1/4″ FNPT

Baldwin™-Series Digital Coolers

Model NameStandard CapacityImpingers (Passive)Impingers (Active)Dimensions (H x W x D)Weight
20410D10-20 LPM
21-42 SCFH
2 x 10 in2 x 10 in15 x 13 x 12 in39 lbs
5210D3-8 LPM
6-17 SCFH
1 x 10 in1 x 10 in15 x 11 x 11 in27 lbs
8210D4-10 LPM
8.5-21.2 SCFH
-2 x 10 in15 x 13 x 12 in38 lbs

Hybrid gas coolers – provide all the benefits of Perma Pure’s Nafion™ based drying technology combined with the functionality of a traditional thermoelectric coolers.

Baldwin Hybrid Gas Coolers

Model NameSample Gas PressureFilter Drain Mechanism*Bypass Port**Float Operated Drain Valve***
PCD-3000-WNegativeANoNo
PCD-3000-W-DPNegativeBNoNo
PCD-3000-PRPositiveCYesNo
PCD-3000-PR-CDPositiveDYesYes

*Filter Drain Mechanism:
A. Filter Drain Eductor compresses incoming air creating a vacuum needed to drain
condensate from the filter
B. Includes a bulkhead fitting to accommodate an external drain pump (not included)
C. Liquids collected at the bottom of the filter bowl are pushed out of the filter by the sample
gas pressure via the metering tube and out of the filter drain port
D. Liquids collected at the bottom of the filter bowl are pushed out of the filter by the sample
gas pressure and into the float operated drain valve. The drain valve prevents sample gas
from escaping into the drain line.

  1. **Bypass port can be used to lower lag times for applications where a faster response
    time may be desirable
  2. ***Float operated drain valve prevents sample gas from escaping into the drain line

Baldwin eCool Sample Gas Coolers. A revolution in gas sample conditioning, the Baldwin-Series eCool™ coolers offer all the water removal features of the “Classic” series with the additional convenience of digital controls for remote monitoring and data collection.

  • Remote control and monitoring of probe, sample line and cooler
  • Digital control via custom windows application over a network or Modbus over TCP/IP
  • CSA Rated Class I, Division II – e5500XP, e5800XP, e5900XP
  • CE Marked

Baldwin eCool Digital Thermo Electric Cooler

Model NameHeat Exchanger PassiveHeat Exchanger ActiveDimensionsWeight
e5300 1 x 5 in 1 x 5 in 11 x 7 x 11 in HWD, 29 x 18 x 29 cm HWD 20 lbs, 9 kg
e5400 2 x 5 in11 x 7 x 11 in HWD, 29 x 18 x 29 cm HWD20 lbs, 9 kg
e55001 x 10 in1 x 10 in14 x 13 x 13 in HWD, 36 x 33 x 33 cm HWD37 lbs, 17 kg
e5500XP1 x 10 in1 x 10 in14 x 13 x 13 in HWD, 36 x 33 x 33 cm HWD39 lbs, 18 kg
e5800 2 x 10 in14 x 13 x 13 in, HWD, 36 x 33 x 33 cm HWD37 lbs, 17 kg
e5800XP2 x 10 in14 x 13 x 13 in HWD, 36 x 33 x 33 cm HWD39 lbs, 18 kg
e59002 x 10 in2 x 10 in14 x 13 x 13 in HWD, 36 x 33 x 33 cm HWD39 lbs, 18 kg
e5900XP2 x 10 in2 x 10 in14 x 13 x 13 in HWD, 36 x 33 x 33 cm HWD41 lbs, 19 kg

See also: FF 250 Series Filters

ETA Process Instrumentation

sales@etapii.com
119 Foster Street, Bldg. #6,
Peabody, MA 01960

Tel: (978) 532-1330
Fax: (978) 532-7325

Visit Our Sister Companies